Siemens HMI tp1200 smart server activate

Hi  Please, is it ok to activate tp1200 smartserver using automation license manager? I need to add pc station and I don't have the wincc RT file, just want to see machine operation Status from the...

View Article


Second network on a S7 1214 setup

I need to use a S7 1214 PLC and connect to two different IP-addresses. The PLC will be connected to three other 1200 systems on "network 1" collecting data on a Profinet "machine network". Customers...

View Article


Image may be NSFW.
Clik here to view.

Tia Portal Program Upload Error

Dear All i got this error when i upload program from plc to PC  then this error is shown. if i continue then TIA Portal Crashes. Kindly suggest me a solution .    PLC : Siemens 1200 Cable : MPI

View Article

S7-200 / S7-Microwin Help

Good Morning, Hoping someone with some Siemens experience can give me a hand with this one. Customer has a S7-200 cpu, which has a 6GK7 243-1EX01-0XEO ethernet module attached. Initially I connected...

View Article

Conversion from S5 to S7(TIA)

Hi All , I am working for a project to convert S5 PLC to S7 PLC system for a Concrete Block making machine of OMAG . I request guidence and support from experts who have experience in OMAG PLC system

View Article


TIA portal V19 connection with HMI panel not wotking

Hello! I have TIA portal V19 version installed and I have a project with CPU 1513 PN and KTP900 panel. Connection between panel and CPU is not working. With older version, V18 it is working fine. Any...

View Article

S5 Program

Hi! I am converting a simple S5 program to relay logic for a customer but I am not familiar with S5 programming. I'm just not exactly sure what each letter represents. I have the manual but it doesn't...

View Article

Interfacing g120c-pn with any modbus plc

Hi I have g120c-pn vfd and need to connect it with delta DVP plc. The plc has rs485 interface but the drive has profinet interface. Is there any way to solve it? Can it be done by using any...

View Article


SIMATIC S7-300 training kit STOP LED blinking

SIMATIC S7-300 training kit not working. PLC doesn't go to RUN mode, and still in STOP mode all the time. STOP mode led is blinking every 1 second, even when I press MRES key. This is a video I...

View Article


Siemens Scalance SC636-2C NAT config

Hi all, I have some difficulties with programming a NAT config in my Scalance SC636-2C When programming the NAT-table i'm not able to reach my devices.  143.26.58.XXX is public network adress,...

View Article

Communication Problem S7-1200

Dear Experts,  i am facing a problem regarding plc to plc communication .  i have 2 plc that are communicating through industrial switch . one plc is s7-1200 and second is Fatek FBS-40ma with FBS-CBE...

View Article

Image may be NSFW.
Clik here to view.

Software module without output?

I have bought a Siemens Logo with software and I am a beginner. Testing with ladder programming and have a problem. When I use timers of various kinds, for example on/off delay, I get no output Q?...

View Article

Image may be NSFW.
Clik here to view.

WinCC flexible compile error - stripping font

hello everyone, Got a PLC/HMI project from machine vendor. The problem is that HMI does not compile. Both fonts are present of course but message suggest error stripping the font.... Sometimes there...

View Article


Phoenix Contacts GSD Files for Step 7

Hello, I am wanting to add the following Phoenix Contact units to an existing Profibus network on a SIMATIC Step 7 configuration and I need the GSD files. Could anyone please help as to where I can...

View Article

Virtual keyboard off screen

Hello all,           The virtual keyboard has slid mostly off our operator screen.  There is only a sliver left showing and not enough to grab it by to move it back.  Does anyone know how to move it...

View Article


Smart 700 IE V3

What software use to get program of Smart 700 IE v3 Siemens HMI and where can I get software free for this.

View Article

Image may be NSFW.
Clik here to view.

Siemens CPU314 Analog Input not showing

Hi, I have a CPU314 with an analog input card that sets to 0-10VDC input.I inject the voltage from a multimeter but it does not showing any reading on TIA Portal V17. We tried on all channels but...

View Article


S7300 with Omron NB HMI Communication

So, I have a Siemens S7300 CPU314 PLC and Omron NB10W HMI. Now I want to communicate between this device. I have a Siemens Profibus DP connector. so, can I connect this bus connector through Omron NB...

View Article

Do S5 EPROM age out?

Hello Again,  I recently replaced the original 941 CPU in a S5 / 155  from 1994   with a refurbished 941 from Classic Automation.  It installed and powerup fine, did an overall reset to read program...

View Article

Optimized Block Access in TIa Portral

Dear All, i have S7-1200 with seimens hmi.  Problem is that Siemens Hmi is Far Old and now touch is problem . So In replace Weintek Hmi is selected. -----the problem i am facing the data block is...

View Article

Image may be NSFW.
Clik here to view.

MB_CLIENT Error

  Hi there! I'm trying to communicate a S7-1500 CPU via Modbus TCP with an CJ2 PLC using a CP1W-MODTC61 card. I configurated the MB_Client and the CP1W-MODTC61 was also configured as the attached...

View Article


Image may be NSFW.
Clik here to view.

Allen Bradley 1783 NATR Communication Issue with Siemens S7 PLC

We have machine that is running on Siemens S7 PLC and we have mostly Rockwell Automation/Allen Bradley hardware in the facility. I am working on getting a 1783 NATR to talk to the Siemens PLC. I am...

View Article


Siemens and Prosoft PLX32-EIP-PND connection fault

Looking for some advice:  We have some automation systems which have some Siemens devices communicating with Allen Bradley Compact Logix using Prosoft PLX32-EIP-PND communication gateways.  From a...

View Article

simatic S7-200

Hi colleagues, looking for  help to troubleshoot the S7-200/226XM/AC DC/RLY unit. I have experience and certification with AB/Omron but nothing with Siemens, neither   programming software and cable....

View Article

Image may be NSFW.
Clik here to view.

How to read shunt current with a PLC?

Hello FriendsWe have a machine that magnetizes the part, to read the current it uses a digital panel meter but you only can see the current in this display.This Panel Meter is obsolete and needs to be...

View Article