Migrating to Siemens
Hi everyone! Can someone share their ideas on how should I start migrating my Mitsubishi program to Siemens PLC? What are the key points do I need to keep in mind when doing migration? Thank you!
View ArticleS7 200 SEG INSTRUCTION
Hello guys. We are trying to replace a S7 200 PLC at our station with S7 1200. We are reading the program on the S7 200 and recreating the same on the S7 1200. However, we have encountered the SEG...
View ArticleSiemens S7 v 5.5 configure fanuc profinet cp1616
Hi Guys I have some issues with profinet configuration Siemens step 7 v5.5 Fanuc robot profinet card cp1616 I have 8 byte safety 16 byte DI16 byte DOI setup DI and DO. No error.But I have safety comm...
View ArticleRemote connection using eWon
Hi All I am using a eWon unit to give me access to a remote network (IP range 192.168.0.***) using TIA portal V14, which connects to 5 S7-1200 PLC's ,1 LOGO , 8 basic HMIs plus 7 other devices which...
View ArticleCommunication via MPI
Dear All, In my plant we have about 10 PLCs (6 s7 400 cpu & 4 s7 300 )Siemens communication done using MPI protocol I face the following problem we have (ring connection) when I try to monitor...
View ArticleLOGO! 8 TIA portal WinCC
Hi all experts, I am LOGO! 8 PLC programmer, and now I am beginning to start SCADA developement. I want to ask which software should I install ?, 1. TIA portal with Siemens SIMATIC STEP 7 Professional...
View ArticleM7 486 SIEMENS cpu
Dear all , I have PLC M7 486 and connected encoder on EXM card 478 on the same rack I need to know encoder address on PLC programmer was written in C language
View Articlesimotion MMC img file
Hello I have a SIMOTION MEMORY CARD 16MB for C230-2. Order No: 6AU1700-0AA01-0AA0 That formatted with windows. I need image file from Simotion MMC 16MB for write to This MMC with s7 img writer....
View Articlesimotion MMC img file
Hello I have a SIMOTION MEMORY CARD 16MB for C230-2. Order No: 6AU1700-0AA01-0AA0 That formatted with windows. I need image file from Simotion MMC 16MB for write to This MMC with s7 img writer....
View ArticleS7-200 (Step7 Micro/win) - How to change language
Hi guys, I have opened a program and everything was marked was " ? " so i changed the language from English to Chinese. Now, i dont see any ? marks but all i see is Chinese characters. Is there a way...
View ArticleHow is logic stored in S7 PLCs?
Hi, fairly new to Siemens platform but have been around PLCs in general for a long time. I have been told that some programming formats run more efficiently than others within the PLC (ie ST vs LAD)....
View Articlehow to configure input/output modules in step 7 micro/win?
Hi guys, I am trying to add an EM 223 module in step 7 micro/win program. I am new to this siemens S-200. Can someone help with this? Thanks
View ArticleSIEMENS S7 200
Hello all. I m new with PLCs , just started learning them and I'm trying to create a small program in Lad Micro WIN. For some of you guys might be very easy. Below I'll try to explain Button...
View ArticleCounter module FM450-1
Dear all, the following error happened with me as following 1-power cut happened 2-rack with DO wasn't working "meaning no DO on plc module or from PLC but from function was active & some DO was...
View Articlektp700 basic with profibus dp +S71241 CPU+CM1243-5
Gentlemen, I'm new to Siemens and now working on a project for my client. I have a S7 1241 cpu, CM1243-5 com module, a KTP700 hmi prifibus dp. The hmi is connected to the CM1243-5 via profibus cable....
View Articles7 300 AND WINCC flex
Hello guys, Hardware : Laptop with step7, WINCCFLEX ip 192.168.0.223 CPU 315 IP 192.168.0.1 3x 8 input modules 3x 8 output modules program...
View ArticleOptimized Blocks
Hello everyone, Are there any alternatives to WinCC at the moment that can handle using optimized blocks. In most other SCADA software, while importing tags, the option to optimize blocks should not...
View ArticleLOGO! SOFT COMFORT V8.2 FULL
Hello Experts, I have recently started to learn about PLC and Industrial Automation. I got Logo Soft Comfort demo software which cannot communicate with the hardware. How/Where (link) can I get a full...
View ArticleS7-300 & SSD Crash
Hello all! i am a new registered member of this forum, i have been reading and following here for a long time, and it has a lot of helpful information and tips, so thank you for that! The reason i now...
View ArticleComunication PLC S7-1200 Witn NA-9188 Ethernet
Hello evreybody, My name is Tinh I have question.I want to connect PLC S7-1200 with NA-9188(ethernet). NA-9188 have file NA9188.eds but it do not have file GSD.How to add file *.EDS in to TIA Portal...
View Article