TIA portal V19 connection with HMI panel not wotking
Hello! I have TIA portal V19 version installed and I have a project with CPU 1513 PN and KTP900 panel. Connection between panel and CPU is not working. With older version, V18 it is working fine. Any...
View ArticleS5 Program
Hi! I am converting a simple S5 program to relay logic for a customer but I am not familiar with S5 programming. I'm just not exactly sure what each letter represents. I have the manual but it doesn't...
View ArticleInterfacing g120c-pn with any modbus plc
Hi I have g120c-pn vfd and need to connect it with delta DVP plc. The plc has rs485 interface but the drive has profinet interface. Is there any way to solve it? Can it be done by using any...
View ArticleSIMATIC S7-300 training kit STOP LED blinking
SIMATIC S7-300 training kit not working. PLC doesn't go to RUN mode, and still in STOP mode all the time. STOP mode led is blinking every 1 second, even when I press MRES key. This is a video I...
View ArticleSiemens Scalance SC636-2C NAT config
Hi all, I have some difficulties with programming a NAT config in my Scalance SC636-2C When programming the NAT-table i'm not able to reach my devices. 143.26.58.XXX is public network adress,...
View ArticleCommunication Problem S7-1200
Dear Experts, i am facing a problem regarding plc to plc communication . i have 2 plc that are communicating through industrial switch . one plc is s7-1200 and second is Fatek FBS-40ma with FBS-CBE...
View ArticleTIA_Portal_V16 different variants?
have not used Siemens in a while, but need to dump modified project into one of machines. modified project was done in different version so i need to get the TIA portal v16. I notice that there are...
View ArticleSoftware module without output?
I have bought a Siemens Logo with software and I am a beginner. Testing with ladder programming and have a problem. When I use timers of various kinds, for example on/off delay, I get no output Q?...
View ArticleWinCC flexible compile error - stripping font
hello everyone, Got a PLC/HMI project from machine vendor. The problem is that HMI does not compile. Both fonts are present of course but message suggest error stripping the font.... Sometimes there...
View ArticlePhoenix Contacts GSD Files for Step 7
Hello, I am wanting to add the following Phoenix Contact units to an existing Profibus network on a SIMATIC Step 7 configuration and I need the GSD files. Could anyone please help as to where I can...
View ArticleVirtual keyboard off screen
Hello all, The virtual keyboard has slid mostly off our operator screen. There is only a sliver left showing and not enough to grab it by to move it back. Does anyone know how to move it...
View ArticleSmart 700 IE V3
What software use to get program of Smart 700 IE v3 Siemens HMI and where can I get software free for this.
View ArticleSiemens CPU314 Analog Input not showing
Hi, I have a CPU314 with an analog input card that sets to 0-10VDC input.I inject the voltage from a multimeter but it does not showing any reading on TIA Portal V17. We tried on all channels but...
View ArticleS7300 with Omron NB HMI Communication
So, I have a Siemens S7300 CPU314 PLC and Omron NB10W HMI. Now I want to communicate between this device. I have a Siemens Profibus DP connector. so, can I connect this bus connector through Omron NB...
View ArticleDo S5 EPROM age out?
Hello Again, I recently replaced the original 941 CPU in a S5 / 155 from 1994 with a refurbished 941 from Classic Automation. It installed and powerup fine, did an overall reset to read program...
View ArticleDo S5 EPROM age out?
Hello Again, I recently replaced the original 941 CPU in a S5 / 155 from 1994 with a refurbished 941 from Classic Automation. It installed and powerup fine, did an overall reset to read program...
View ArticleSiemens TIA Portal 16 Graph Language
Hello there, I have installed TIA Portal V16. There is a logic programming language called "Graph" in the siemens TIA Portal. This language is not installed by default in the TIA Portal. How to...
View ArticleOptimized Block Access
Dear All, i have S7-1200 with seimens hmi. Problem is that Siemens Hmi is Far Old and now touch is problem . So In replace Weintek Hmi is selected. -----the problem i am facing the data block is...
View ArticleOptimized Block Access in TIa Portral
Dear All, i have S7-1200 with seimens hmi. Problem is that Siemens Hmi is Far Old and now touch is problem . So In replace Weintek Hmi is selected. -----the problem i am facing the data block is...
View ArticleOptimized Block Access in TIa Portral
Dear All, i have S7-1200 with seimens hmi. Problem is that Siemens Hmi is Far Old and now touch is problem . So In replace Weintek Hmi is selected. -----the problem i am facing the data block is...
View Article