HMI panel / display for Siemens LOGO! 8 ethernet
hi, I'm trying to find out what kind of HMI panels can be used for a LOGO!8 ethernet plc. are panels from simens that can be used... they are a bit expensive
View ArticleWF723A 6FM1723-3AA10
Hello, i have trouble with FM card WF723A 6FM1723-3AA10 mounted in S7 adaptor. I have not SW with commnet, I have only downloaded version of sofware. The proble is: Axis C doesn´t make correctly...
View ArticleKTP 400, Recipe problem!
Hello, I am doing a project that requires the use of recipes, but I am having some difficulties. First I am trying the code with simulations and the thing that is not working is that the value of...
View ArticleTIA portal s7-1212c incorrect software version
Ok I'll try a different angle of attack. I have acquired an S7-1212c unit. It is just too new for my TIA portal, which is V 15.1 The new PLC I have has firmwear 4.5 the TIA portal I have only supports...
View ArticleProfibus Address Not Working
I am having a problem on S7/Profibus. There are a number of identical ET200 RIO nodes. While the equipment was down between orders a fault appeared for loss of one of the nodes on inspection the BF...
View ArticleWorking with rate of change and decimals in TIA portal
I am working on a PLC program that requires an analog valve to close a given percentage in a given time in seconds. I give the start position, the final position, and the time. I calculate the rate of...
View ArticleSinamics S120 hoding brake issue
Hello, everyone, Drive: S120 with CU310-2 PN Safe brake module: 6SL3252-0BB01-0AA0 Servo motor: 1fk7032-5ak71-1vv3-z After 5 years of trouble-free operation: Alarm 7930 - Brake control error[10]...
View ArticleProblem Step7 5.6 Windows 10
Hello to all the forum, I have a problem with the siemens Step 7 5.6 software on Windows 10 64 bit build 1803, in other words I have no interfaces present on the software. How can I fix? Thank you
View Articlelicense... step 7 basic...
Hi.. then it happened I thought I had a basic license for step 7 but ... I don't and the 21 day test period is over.. now I have tried to find out how to buy a license but 4000USD can it be right.. I...
View ArticleSiemens TIA Portal 16 Graph Language
Hello there, I have installed TIA Portal V16. There is a logic programming language called "Graph" in the siemens TIA Portal. This language is not installed by default in the TIA Portal. How to...
View ArticleGlobal DB to output string
Hi guys.. so it's tight again with my knowledge.. I have made a Data Block. In that data block I have entered 8 text messages. ( String ) I can get them out in a local variable... but I can't really...
View ArticleSiemens Logo PLC
Hello Experts Can someone please tell me if Communicating software for Siemens Logo PLC is downloadable? Regards
View ArticleFloating license
Hi, I got the floating license so I could have copies on my desktop computer (for development) and the laptop (for installations). Is this possible? The laptop won't have access to the office network...
View ArticleError 288:47 Fail to online monitor s7 400 CPU
This is not the first time we online upload and monitor PLC program from S7400 CPU. After we upload the program from the CPU, we are unable to online monitor. May I ask what problem could it be? I...
View ArticleHow do I enter value into Dint tag?
Hi, I created a tag(paul) as dint. I have paul.%x0 and paul.%x1 and I can not modify them (to make them on/off) is it possible to enter a value into the monitor value? if possible, I would like to put...
View ArticleSiemens HMI tp1200 smart server activate
Hi Please, is it ok to activate tp1200 smartserver using automation license manager? I need to add pc station and I don't have the wincc RT file, just want to see machine operation Status from the...
View ArticleSecond network on a S7 1214 setup
I need to use a S7 1214 PLC and connect to two different IP-addresses. The PLC will be connected to three other 1200 systems on "network 1" collecting data on a Profinet "machine network". Customers...
View ArticleTia Portal Program Upload Error
Dear All i got this error when i upload program from plc to PC then this error is shown. if i continue then TIA Portal Crashes. Kindly suggest me a solution . PLC : Siemens 1200 Cable : MPI
View ArticleS7-200 / S7-Microwin Help
Good Morning, Hoping someone with some Siemens experience can give me a hand with this one. Customer has a S7-200 cpu, which has a 6GK7 243-1EX01-0XEO ethernet module attached. Initially I connected...
View ArticleConversion from S5 to S7(TIA)
Hi All , I am working for a project to convert S5 PLC to S7 PLC system for a Concrete Block making machine of OMAG . I request guidence and support from experts who have experience in OMAG PLC system
View Article