S7-300

Has anyone ever use a Allen Bradley 9300-ENA card with a Siemens S7-300?

View Article


TI / Siemens 505 workshop 505 help

Is anyone experienced with Siemens 505 / FasTrack workshop 505? I have an old GE quick panel that has gone out and now must be replaced. Cant get the program out of it. No one has a documented copy of...

View Article


Simotion Scout

Hello All, On the machine I have the Siemens PLC C240, the program was downloaded propably with the Scout ver 4.1. Now I have open the project with the version 4.4. To change the some program, need I...

View Article

Thousand Separator in WinCC(Tia Portal)

Hello everyone, I was wondering if you could help me with something i'm trying to do...in WinCC(Tia Portal V13) i have some output fields that display real numbers..what i'm trying to do is make them...

View Article

Factory I/O 3D simulation connect to Tia Portal V13

With Factory I/O you can learn and test your program with a 3D view system Support many automation regular machine,support digital and analog signal too Have a look on this...

View Article


profibus master/slave communication between s7-300 and s7-400

Hi,I would like to establish a profibus master/slave communication between s7-300 and s7-400. but i can not configure it ???  

View Article

MicroLogix1400 LOGO! software

hello everyone, someone had set up a MicroLogix 1400 controller with logic done using LOGO! software. i am new to this equipment and i badly need some help on how to connect my PC to MicroLogix 1400...

View Article

Step7 on remote server

Hi, I was wondering if anyone have experience with Tia Portal Step7 v.14 and Step7 Classic v.5.5 located on a remote server? We have several persons working on our PLC's. As it is they all have their...

View Article


Image may be NSFW.
Clik here to view.

Intellisys Modbus COM Port to DB9 CM 1241

Dear All   Sorry for my English I have Siemens CM1241 (picture attach) and need to communicate with Intellisys XE 90 via Modbus RTU, period. The problem is, form XE 90 the connector is Phoenix Contact...

View Article


TIAPortal: How to delete users during run-time?

There is a standard view called "User view" that you can drag in to your HMI project on TIAPortal. It allows you to create new users, and edit users during run-time (i.e. from the HMI screen itself,...

View Article

Detect value change in data block even if value is same as before

Hi, I was wondering if it's possible to detect a changed/updated value in a data block even if the value remains the same as before. The reason I ask is because we have a SCADA system providing a...

View Article

Pcs7

Hi. everyone  I m new to use pcs software is there anyone to hepl me about this software that how i start the programmering H

View Article

Limiting on-line connections to a S7-1500 PLC

Hi, I was wondering if there is a way to limit the number of allowed on-line connections at a time to a PLC? Like can you somehow set in the PLC parameters that only 1 'connection' can be on-line in...

View Article


S7-400H Redundant Confogration

Dear Expert Is necessary to have both CPU (Master & Slave) same program blocks or only master PLC should have S7-program with blocks  Best Regards Ali 

View Article

Logo!8 sensor compatibility/display

Hi there,  I am brand new to the world of PLCs. I'm working on a project and we will be using the LOGO! 8. We will be monitoring a tractor's ground speed, wheel speed, (wheel slip using those two),...

View Article


Image may be NSFW.
Clik here to view.

Siemens Timer Help..

We're newbies to Siemens due to being a 90% Mitsubishi plant... T130 below, we believe, is set to 0ms. Then set via 'TV' under the DB105.DBW260 address. 1. What is the 'S5TH#' infront of the 0ms 2....

View Article

profibus packet problem

I am new  in Siemens. I want to connect the oscilloscope to the TX and RX of the profibus  between PC and PLC . That is,I can observe its  wave and  packet. But , I  don't know how to understand this...

View Article


Image may be NSFW.
Clik here to view.

Applicom PCI board

Dears, I've Industrial computer containing  applicom PCI Board 32K  which connecting to S7-300 PLC. The hard disk of the computer has fault and then I replaced it with a new one and then restored the...

View Article

s7-226 modbus master?

it can s7-226 communicate with modbus master or only with slave? i want him to make master in inverter… I can?

View Article

Image may be NSFW.
Clik here to view.

Problem with TIME variables

Greetings everyone, I have one problem with my program (I am using S7 1214 DC/DC/DC). I am creating a program for measuring total time between some actions for three work shifts. Variables %MD1, %MD2...