HMI I/O Tag addressing

Hi all, I am sure this has been done many times but I am relatively new to Siemens so please bear with me.   I am using Simatic manager Step 7 for the plc programming and TIA portal 13 sp1 for the HMI...

View Article


Slave Relays

I am going to install a Siemens PLC on a project. It has relay outputs and I am in 2 minds whether I should slave the outputs through relays before driving contactors like ABB's A-lines or just...

View Article


IM308c gives me an error "Incorrect Mode"

I am currently trying to set up an IM308c Profibus DP Module to use with an S5-135U system using two 928B processors in Multiprocessing mode. Module will only be accessed by one CPU and the slave is...

View Article

PLC siemens

Hi everybody I have PLC Siemens s7-200 smart CPU sr20 and I want to know ,what is software I need and the cable for PC Best regards

View Article

Image may be NSFW.
Clik here to view.

floating and Nonfloating I/O modules

Hello everyone,        I'm checking out the manual fot the S5 ET 100U due to some power supply problems in the factory I work. I've worked in projects with S7 PLCs and ET 200s, but these old PLCs and...

View Article


Image may be NSFW.
Clik here to view.

Connecting to Sinamics G120 by Starter/Scout via CPU S300 gateway

Hello. I have CPU S319-3 PN/DP which connected with Sinamics G120 by profibus. I have connect with cpu by ethernet. I made setting as explained in help, but it doesn't work. I use Simotion Scout...

View Article

Siemems Set Reset with singal input

Dear all I need one help i have one application where 1st time any input comming then one output should be SET. and when 2nd time same input will come this output should be RESET.

View Article

Compile ALL

Is it possible to do a "Compile All" in TIA Portal Version 14 when programming offline? Thanks!

View Article


Image may be NSFW.
Clik here to view.

S7 300 to Ignition

Hi All, This is my first project with Ignition so please bear with me. I'm setting up a system in which I'll be communicating a Siemens CPU 315 (CPU 1) with the existing CPU 314 (CPU 2) via MPI. The...

View Article


Tisoft analog alarm programming

I'm programming an analog alarm and I think there are 2 ways to do this.  I can use the CMP block and turn a relay on if the value goes LT or GT a setpoint or I can acually configure an alarm using...

View Article

USB Error

Hello All,      I am wondering if anyone has seen this error before? The SIMATIC USB Service service failed to start due to the following error:  The service cannot be started, either because it is...

View Article

Communication Between Two VFD

Hi i am currently working on a PU foaming machine actually Machine have itself one 4Meter conveyor and speed of that conveyor autamatic adjusting depending on Density of foam. after machine i have 3...

View Article

Siemens S7-1500 profibus communication with rotork actuator

I am trying to set up a Profibus DP connection with a Rotork actuator that controls a valve. Since i dont have a plc or an actuator, I have to try to do everything in the simulator. I have imported...

View Article


WinCC Data Monitoring/Reporting

Hi! If you have any idea, please share and bear with me. I have upcoming project and my client project specs is that they need visual representation of the instruments(which are all analog...

View Article

Siemens S5 Backup Battery

Hello All,   I have been tasked with sourcing some spare parts for a cabinet housing Siemens S5 PLC's. I have managed to source all of the CPU's, output cards, input cards, EPROM etc, I am currently...

View Article


Siemens VFD

How to use Siemens VFD with 3phase motor to control it speed with frequency ...

View Article

First fault detection

I have 14 bits, each is set when a particular fault occurs, the problem is once 1 fault occurs and the machine stops it then causes more "red herring" faults. I need to detect which fault happened...

View Article


Videojet 1620 with Siemens

Hi guys, currently working on the communication with videojet 1620 printer (Continuous Inkjet Marking), in there operators manual...

View Article

Limiting on-line connections to a S7-1500 PLC

Hi, I was wondering if there is a way to limit the number of allowed on-line connections at a time to a PLC? Like can you somehow set in the PLC parameters that only 1 'connection' can be on-line in...

View Article

pc to cpu

hi i am new to siemens ,can someone tell me the communication setting to monitor program from my pc.I am having step 7 ,the cpu is IM15-8 pn dp cpu.   thanks    aakash